Products
-
Renji Amies Transport Medium 2ml/10ml, Nasopharyngeal Swabs & Bags (50 Sets)
SKU: SL901AALiquid Amies Medium is a balanced salt solution formulated to maintain an osmotic balance similar to the natural condition mammalian systems. Liquid Amies medium is used for its effective buffering capacity at in vivo neutral pH. Liquid Amies includes: Sodium chloride Potassium chloride Calcium chloride Magnesium chloride Monopotassium phosphate Disodium phosphate Sodium thioglycolate Molecular grade water Appearance The liquid Amies is a colorless, transparent solution. It may have a cloudy appearance due to the salts present in the medium. Handling This product is produced for in-vitro use and is suitable for research and manufacturing only. It is the end user's responsibility to determine the suitability and obtain sufficient validation for each application of use. The medium has not been reviewed by the FDA. Instructions for Use Check the expiration date of the product and do not use products that have expired. Do not use the product if it is damaged or if foreign substances are found in the product. If necessary, dispense the appropriate amount of product into a suitable container. Do not use it if original container is broken or any foreign matter is found. Safety Information Non-toxic Non-flammable Avoid contact with skin and eyes Do not ingest PACKING SPECIFICATION 50 Testing Kits/ box MAIN COMPONENTS Number Composition 50 Testing Kits/box 1 Sampling Tube (with 2ml Amies solution) 2ml x 50 tubes 2 Nasal Swab 50 pcs/box 3 Specimen Bag 50 bags/box 4 Manual 1 STORAGE CONDITIONS Store at temperature 5 - 25 °C
$50.00
-
Renji VTMs 2ml/10ml, Nasopharyngeal Swabs & Bags (50 Sets)
SKU: SL901APACKING SPECIFICATION 1 Box of 50 Testing Kits INTENDED USE It is used for the collection and transportation of clinical COVID-19, Influenza, Avian Influenza, Hand, Foot and Mouth Disease, Measles, Chlamydia, Mycoplasma, and Ureaplasma specimens. MAIN COMPONENTS Item Quantity Sampling Tube (with 2ml VTM solution) 2ml x 50 tubes Nasal Swab 50 pcs/box Specimen Bag 50 bags/box Manual 1 STORAGE CONDITIONS Store at temperature 5 - 25 °C. SAMPLE REQUIREMENTS Applicable sample types: Oropharyngeal, Nasopharyngeal, Saliva, Sputum, and other clinical samples. Storage and transportation of samples:After the sample is collected, it should be transported to the corresponding laboratory for testing within 48 hours, and the storage temperature is 2-8°C. If it cannot be transported to the laboratory within 48 hours, it should be stored at -20°C or below and sent to the corresponding laboratory within one week. The sample should avoid repeated freezing and thawing. INSTRUCTIONS INSTRUCTIONS CONTINUED Mark the sample information on the tube. According to different sampling requirements, use a sampling swab to sample at the corresponding area. Hold the handle to gently insert the sampling swab into the sampling site, gently rotate the swab 3-5 times and slowly take out. Put the extracted sample into the sampling tube, break the swab at the breaking point and leave the swab head in the tube. Tighten the tube cap to complete the sampling. Freshly collected clinical specimens should be transported to the laboratory within 48 hours at 4 °C. Those that cannot be sent to the laboratory within 48 hours should be stored at -20 °C or below. The conventional sampling methods are as follows: Nasal swab: Insert the head of the swab gently into the nasopalatine part of the nasal canal, stop for a while, and then slowly rotate it out. Repeat to other nostril with a new swab. Once specimen is collected, immerse the head of the swab into the sampling solution, and discard the tail. Oropharyngeal swab: Use a swab to wipe the bilateral pharyngeal tonsils and posterior pharyngeal wall. Immerse the swab head in the sample solution and discard the tail. Mouthwash: Gargle in the mouth with 10ml of normal saline. Let the patient's head tilt back slightly and make an "Oh" sound. Let the saline rotate in the pharynx then collect the wash with an empty 50ml sampling tube. Nasal wash: While seated, the patient tilts their head slightly back and is injected with 50 ml of normal saline into one nostril with a pipette. Collector instructs the patient to simultaneously sound "K" to close the pharyngeal cavity. The patient then bows their head to let the saline flow out as the fluid is collected with an empty 50 ml sterilized tube. Repeat this process to wash the other nostril. Nasopharyngeal extract: Tracheal and bronchial secretions are often collected using this method. Mucus is drawn from the nasopharynx with a collector connected to a negative pressure pump. First insert the collector head into the nasal cavity, turn on the negative pressure, rotate the collector's head, and slowly push it out. Collect and draw the mucus, and rinse the collector three times with 5 ml of the sampling solution. Autopsy tissue specimens: Collect autopsy tissue specimens if necessary, to separate sample components. The specimen is autopsy tissue. Samples of mycoplasma, chlamydia, urea plasma: for males, inserts the sterilized swab into the urethra about 2cm, rotate, and take out. Let the material rest for several seconds. For females, wipe out the cervical mucus and inserts the sterilized swab into the cervical canal 1cm-2cm to take out material.
$50.00 $30.00
-
RephiBio Filter for Genie (1 Count)
SKU: RAFFB0201Rephibio Filter RAFFB0201 is a disposable final filter for ultrapure water in biological applications to effectively remove endotoxin, RNases, DNases and bacteria from water.RephiBio filter is suitable for use with cell culture, molecular biology or other biochemistry applications that require biologically active impurities-free ultra-pure water.Every filter is integrity tested. Each product package comes with a quality certificate stating its performance specifications and operating conditions. Package:1 / PK Specifications: Material of shell: PP (Polypropylene) Material of membrane: Positively charged Nylon-66, double layer Pore Size Rating: 0.2 μm Maximum Operating Temperature: 80 ℃ Maximum Operation Pressure: 0.40 MPa (4 bar) @ 30 ℃ Maximum Flow Rate: 2 L/min Connection: ¼ NPT Product Water Specifications (when used in a clean environment) Pyrogen : <0.001 Eu/mL RNases: < 0.5 pg/mL (non-detectable level) DNases : < 10 pg/mL (non-detectable level) Bacteria : < 0.01 cfu/mL Package Dimensions & Gross Weight: Length X Depth X Height (mm): 140 X 80 X 90 Gross Weight (kgs): 0.10 Suitable for the following water systems: Direct-Pure Genie Direct-Pure UP Direct-Pure EDI Direct-Pure adept PURIST PURIST Pro
$425.00
-
RephiDuo H Pack Cartridge RR300Q201 (1 Count)
SKU: RR300Q201RephiDuo H Pack RR300Q201 is a high-purification pack for Direct-Pure water system to remove ionic impurities from water. Specifications: Burst pressure: ≥15 bar Flow rate: ≥2 L/min(Feed pressure ≥ 2 bar) Height: 331 mm Package Dimensions & Gross Weight Length X Depth X Height (mm): 460 X 220 X 130 Gross Weight (kg): 2.6 Suitable for the following water systems: Direct-Pure UP PURIST Pro
$374.00
-
RephiDuo P Pack Safeguard Cartridge RR300CP01 (1 Count)
SKU: RR300CP01RephiDuo P Pack RR300CP01 is designed to remove particles, organic compounds and free chlorine from tap water. This protects the reverse osmosis (RO) membrane against mineral scaling, organic fouling and chlorine oxidation. Catalog No.: RR300CP01 Specifications: Height: 331mm Package Dimensions & Gross Weight Length X Depth X Height (mm): 460 X 220 X 130 Gross Weight (kgs): 1.84 Suitable for the following water systems: Direct-Pure Genie Direct-Pure UP Direct-Pure EDI
$291.00
-
RephiDuo U Pack Cartridge Kit RR600Q2KT (1 Set)
SKU: RR600Q2KTRephiDuo U Pack with a 0.2 µm final filter Specifications: Height: 331 mm With a 0.2 μm final filter Package Dimensions & Gross Weight Length X Depth X Height (mm): 0.022m3 Gross Weight (kgs): 4.60 Suitable for the following water systems: Direct-Pure Genie Direct-Pure UP Direct-Pure adept PURIST Pro
$593.00
-
RephiDuo U Pack Cartridge RR600Q201 (1 Count)
SKU: RR600Q201RephiDuo U Pack RR600Q201 is designed for removing ionic and organic contaminants below trace level to match the water quality required for your application. (Dispense filter not included) Catalog No.: RR600Q201 Specifications: Height: 331 mm Package Dimensions & Gross Weight Length X Depth X Height (mm): 460 X 220 X 130 Gross Weight (kg): 2.6 Suitable for the following water systems: Direct-Pure Genie Direct-Pure UP Direct-Pure adept PURIST Pro
$406.00
-
RephiDuo U Pack Cartridge, Low TOC RR600Q301 (1 Count)
SKU: RR600Q301(Dispense Filter not included) Specifications: Height: 331 mm Low TOC Package Dimensions & Gross Weight Length X Depth X Height (mm): 460 X 220 X 130 Gross Weight (kg): 2.6 Suitable for the following water systems: Direct-Pure Genie Direct-Pure UP Direct-Pure adept PURIST Pro
$499.00
-
Replacement 0.2 um PES High Flux Filter for Millipore MPGP04001/SIMFILTER/MPGP02001/MPGL04GK20 (1 Count)
SKU: RAFFC0250This is a 0.2 µm PES membrane filters designed for the removal of particles and microorganisms from liquids. Membrane is US made. Every filter is integrity tested. Specifications Membrane PES Pleat Support Polyester Shell, Cage, Core, End Caps Polypropylene Nominal Dimensions Lengths: 117 mm (4.6") without fittingsDiameter: 55 mm (2.2") Effective Filtration Area 200 cm2 Pore Size Rating 0.2 μm Minimum Bubble Point 2.5 bar (36 psi) in water Maximum Operating Pressure 4 bar (60 psi) at 25°C Suitable for the following Millipore Systems: Milli-Q Elix Advantage Synergy Simplicity Direct-Q Disclaimer third parties: All product and company names are trademarks™ or registered® trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement by them. All specifications are subject to change without notice. MILLIPORE, MILLI-Q, DIRECT-Q, SIMPLICITY, SYNERGY and ELIX are trademarks of Merck KGaA, Darmstadt Germany.
$192.00
-
Replacement 100L Tank Level Sensor for Millipore FTPF06805 (1 Count)
SKU: RAPF06805This product is compatible to Millipore 100L-tank level sensor. Suitable for the following Millipore systems 100L PE Reservoir Bioland Catalog No. Description Millipore Catalog No. RAPF05380 30L water tank level sensor FTPF05380 RAPF05381 60L water tank level sensor FTPF05381 RAPF06805 100L water tank level sensor FTPF06805 RAPF07743 200L water tank level sensor (with Jack) FTPF07743 RAPF20022 200L water tank level sensor (without Jack) ZF2000022 RAPF07744 350L water tank level sensor (with Jack) FTPF07744 RAPF20023 350L water tank level sensor (without Jack) ZF2000023 Disclaimer third parties: All product and company names are trademarks™ or registered® trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement by them. All specifications are subject to change without notice. MILLIPORE, MILLI-Q, DIRECT-Q, SIMPLICITY, SYNERGY and ELIX are trademarks of Merck KGaA, Darmstadt Germany.
$760.00
-
Replacement 200L Tank Level Sensor for Millipore FTPF07743 (1 Count)
SKU: RAPF07743This product is comparable to Millipore 200L-tank level sensor. Bioland Catalog No. Description Millipore Catalog No. RAPF05380 30L water tank level sensor FTPF05380 RAPF05381 60L water tank level sensor FTPF05381 RAPF06805 100L water tank level sensor FTPF06805 RAPF07743 200L water tank level sensor (with Jack) FTPF07743 RAPF20022 200L water tank level sensor (without Jack) ZF2000022 RAPF07744 350L water tank level sensor (with Jack) FTPF07744 RAPF20023 350L water tank level sensor (without Jack) ZF2000023 Disclaimer third parties: All product and company names are trademarks™ or registered® trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement by them. All specifications are subject to change without notice. MILLIPORE, MILLI-Q, DIRECT-Q, SIMPLICITY, SYNERGY and ELIX are trademarks of Merck KGaA, Darmstadt Germany.
$584.00
-
Replacement 200L Tank Level Sensor for Millipore ZF2000022 (1 Count)
SKU: RAPF20022This product is comparable to Millipore 200L-tank level sensor. Bioland Catalog No. Description Millipore Catalog No. RAPF05380 30L water tank level sensor FTPF05380 RAPF05381 60L water tank level sensor FTPF05381 RAPF06805 100L water tank level sensor FTPF06805 RAPF07743 200L water tank level sensor (with Jack) FTPF07743 RAPF20022 200L water tank level sensor (without Jack) ZF2000022 RAPF07744 350L water tank level sensor (with Jack) FTPF07744 RAPF20023 350L water tank level sensor (without Jack) ZF2000023 Disclaimer third parties: All product and company names are trademarks™ or registered® trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement by them. All specifications are subject to change without notice. MILLIPORE, MILLI-Q, DIRECT-Q, SIMPLICITY, SYNERGY and ELIX are trademarks of Merck KGaA, Darmstadt Germany.
$606.00