{"product_id":"sp-uv1100-uv-visible-spectrophotometer","title":"SP-UV1100 UV-visible Spectrophotometer","description":"\u003cul\u003e\n\u003cli\u003eSaves up to 200 group data \u0026amp; 200 standard curves\u003c\/li\u003e\n\u003cli\u003eData can be restored even after a sudden power failure\u003c\/li\u003e\n\u003cli\u003eAuto setting of wavelength to calibrate the system\u003c\/li\u003e\n\u003cli\u003eWavelength range from 190 to 1100nm\u003c\/li\u003e\n\u003cli\u003eAutomatic Switching between Tungsten \u0026amp; Deuterium lamps\u003c\/li\u003e\n\u003cli\u003eSystem is fully equipped and capable of executing all functions in stand-alone mode\u003c\/li\u003e\n\u003cli\u003eLarge sample for accommodate 5–100mm path length cuvettes with optional holders\u003c\/li\u003e\n\u003cli\u003eOptional application software 'Wave Professional' provides computer control , and other functions such as spectrum scan, time scan(kinetics), multiwavelength scanning \u0026amp; Nucleic\u003c\/li\u003e\n\u003cli\u003eAcid \/ Protein measurement. \u003c\/li\u003e\n\u003cli\u003eWide range of accessories are available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Parameters\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 101.071%; height: 382.282px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"138\" style=\"width: 47.2566%; background-color: rgb(173, 192, 155);\"\u003e \u003ccol width=\"306\" style=\"width: 52.3894%;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; text-align: center;\"\u003e\u003cstrong\u003eOptical System\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; text-align: center;\"\u003eSingle Beam\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"height: 39.1875px; text-align: center;\"\u003e\u003cstrong\u003eLight Source\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 39.1875px; text-align: center;\"\u003eTungsten Lamp(Japan HYBEC) | Deuterium Lamp(Milaras)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; text-align: center;\"\u003e\u003cstrong\u003eSpectral Bandwidth\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; text-align: center;\"\u003e2.0nm\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003eWavelength Range\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 19.5938px;\"\u003e190-1100nm\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003eWavelength Accuracy\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 19.5938px;\"\u003e±0.5nm\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003eWavelength Repeatability\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 19.5938px;\"\u003e≤0.3nm\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003ePhotometric Range\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 19.5938px;\"\u003e-0.3 - 3.0 A, 0 - 200%T\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003ePhotometric Accuracy\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 39.1875px;\"\u003e±0.002 A @ 0.5 A, ±0.004 A @ 1.0 A, ±0.3%T @ 100%T\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003ePhotometric Repeatability\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 39.1875px;\"\u003e≤0.001 A @ 0.5 A, ≤0.002 A @ 1.0 A, ≤0.15%T @ 100%T\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003eStability\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 19.5938px;\"\u003e≤0.002 A\/h @ 500 nm ( after preheat 2 hours)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003eStray Light\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 19.5938px;\"\u003e≤0.05%T @ 220 \u0026amp; 360nm\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003eSample Compartment\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 19.5938px;\"\u003e4-position, 10mm pathlength cuvette\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003eDisplay\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 19.5938px;\"\u003eDot Matrix LCD\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003eOutput\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 19.5938px;\"\u003eUSB Port \u0026amp; Parallel Port ( Printer)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"text-align: center; height: 10px;\"\u003e\u003cstrong\u003ePower Requirements\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 10px;\"\u003e110\/220VAC, 50\/60Hz, 120W\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: center; height: 19.5938px;\"\u003e\n\u003cdiv data-v-503ecf98=\"\" class=\"productDetail_parameter_item_label\" data-font-en-applied=\"true\"\u003e\u003cstrong\u003eDimension[L×W×H]\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 19.5938px;\"\u003e475×360×225mm\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"text-align: center; height: 19.5938px;\"\u003e\n\u003cdiv data-v-503ecf98=\"\" class=\"productDetail_parameter_item_label\" data-font-en-applied=\"true\"\u003e\u003cstrong\u003eWeight\u003cbr\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 19.5938px;\"\u003e14.6kg\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bioland Scientific LLC","offers":[{"title":"Default Title","offer_id":47641161826493,"sku":"SP-UV1100","price":3629.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/1885\/6125\/files\/SP-UV1100-1.webp?v=1783980108","url":"https:\/\/bioland-sci.com\/products\/sp-uv1100-uv-visible-spectrophotometer","provider":"Bioland Scientific LLC","version":"1.0","type":"link"}